Production — Serving IVF Clinics

AI-Powered Embryo
Grading for IVF

EmbryoIQ delivers instant, automated Gardner scoring using a deep learning mega-ensemble of 8 models across 5 architectures. Snap a photo, get a grade — in seconds.

8
AI Models
87.2%
Top Accuracy
TTA Augmentations
0-100
Embryo Score

Multi-Architecture Mega-Ensemble

Combining specialist and multi-task models across multiple resolutions for maximum diagnostic accuracy

🧩

Specialist + Multi-task Hybrid

Each Gardner component (Expansion, ICM, TE) uses the best-performing approach — ensemble for EXP, specialists for ICM and TE.

🔲

Multi-Resolution Input

Models trained at multiple resolutions with PadToSquare — preserving full aspect ratio with zero information loss.

🔄

8-Fold Test-Time Augmentation

Every image is analyzed 8× with horizontal flip, vertical flip, and 90° rotation combinations for robust predictions.

🎨

CLAHE Enhancement

Adaptive histogram equalization improves detail visibility in low-contrast embryo microscopy images.

⚖️

Grid Search Optimized Weights

Ensemble weights are optimized via exhaustive grid search on the validation set for peak accuracy per component.

🧬

Diverse Architecture Ensemble

State-of-the-art CNN and hybrid architectures with advanced pretraining strategies for maximum feature extraction.

Exceeding State-of-the-Art

Benchmark accuracy on independent test set — surpassing Kromp et al. (2023)

87.2
%
Expansion
5-Model Mega Ensemble
86.6
%
ICM
v7 Solo Specialist
80.4
%
TE
v6 Solo Specialist

End-to-End Inference Pipeline

From photo capture to encrypted result delivery — fully automated

📱
Capture
on iOS
🔐
E2EE
Upload
🎨
CLAHE
Enhance
🔄
8-Fold
TTA
🧠
Mega
Ensemble
📊
Gardner +
MedFlux Score
🔒
Encrypted
Delivery

Model Architectures

M1
CNN Backbone A
EXP + ICM + TE
M2
Hybrid CNN-Transformer
EXP + ICM + TE
M3
CNN Backbone B
EXP Specialist
M4
CNN Backbone B
ICM Specialist
M5
CNN Backbone B
TE Specialist
M6
CNN Backbone B
EXP Specialist
M7
CNN Backbone B
ICM Specialist
M8
CNN Backbone C
EXP Specialist

MedFlux Embryo Score

Live Birth-optimized 0-100 scoring system with probability-weighted Gardner components

Score = f( Expansion, ICM, TE ) → 0–100
Proprietary weighted ensemble scoring — AI-predicted Gardner sub-scores are combined using live birth-optimized coefficients
0 — 30
Low
31 — 50
Below Avg
51 — 65
Average
66 — 80
Good
81 — 100
Excellent

Grade Embryos
From Your iPhone

EmbryoIQ integrates directly with your clinical workflow. Capture a microscopy image, receive the Gardner score and MedFlux Embryo Score within seconds — all through an end-to-end encrypted channel.

  • Instant Gardner score (Expansion + ICM + TE)
  • MedFlux Embryo Score 0-100 for ranking
  • Blastocyst verification (non-blasto detection)
  • End-to-end AES-256-GCM encryption
  • High-performance cloud inference backend
  • Results delivered via secure WebSocket
EmbryoIQ Analysis Result
Gardner Score
4AA
Excellent Quality
85
MedFlux Embryo Score
Models
8
TTA Folds

Zero-Trust Architecture

Patient data never leaves the secure envelope

🔐

AES-256-GCM Encryption

Every image and result is encrypted end-to-end. The server processes data in memory only — nothing is stored to disk.

🌐

WebSocket Delivery

Results are pushed back via Phoenix Channels over secure WebSocket — no polling, no exposure, instant delivery.

🏥

HIPAA-Ready Infrastructure

Dedicated EU-hosted servers with process-level isolation, localhost-only inter-service communication, and strict iptables rules.

Ready to Transform Your
Embryo Selection Process?

Join IVF clinics using AI-powered grading to improve patient outcomes.

🍎 Download EmbryoIQ 📧 Contact Us